Soil Report & Contour Survey from Independent Geotechnical Engineer
Site Works are based on 300mm fall (front to back or back to front)
Working Drawings
Structural Engineering Drawings
Connection of Services – Water Mains, Gas Supply, Sewer & Stormwater connection,
Conduit for Telephone & NBN Ready (all connection pointsto be within boundary) sites
up to 600m2
Standard Builders Cat 1 Range Ceramic Floor & Wall Tiles (straight laid) to Wet
areas (refer to plans)
Your choice of builder’s range laminate flooring
Carpet to all bedrooms
2040mm Flush Panel Hinged Doors with Cushion Door Stops with Chrome Lever Door
Handles
Bedroom robes to have vinyl sliding doors
67mm x 18mm MDF Primed Skirtings & Architraves
2 No. Safety Switches
2 No. Hardwired Smoke Detectors
2 No. TV Points (cable to roof space)
LED lightsthroughout house as per electrical plan
TV Antenna
Provisions For NBN
3 coatsystem to internal Walls & Ceilings from Builders’ Standard Colour Palette
Range
3 coat system to external painted areas
Gloss finish to all internal Woodwork
Daiken 8kW Split System to main living area
Rinnai 2.5kW Split System to master bedroom
Ceiling Fans to bedrooms and living area
Chromagen Midea 280lt Heat Pump HP280
Bedroom Robes – Single Melamine Shelving to Robes (1 No. Shelf, 1 No. Hanging Rail)
Pantry – 4 No. Melamine Shelving
Linen – 4 No. Melamine Shelving
Broom – 1 No. Melamine Shelving NOTES Allowance has been made for a H2 soil report.
Rock removal not included $350 per m3
NOTES
Allowance has been made for a H2 soil report. Rock removal not included $350 per m3
7 Star Double Storey Standard Inclusion List
DENEME
7 Star Energy Rating
Soil Report & Contour Survey from Independent Geotechnical Engineer
Site Works are based on 300mm fall (front to back or back to front)
Working Drawings
Structural Engineering Drawings
Connection of Services – Water Mains, Gas
Supply, Sewer & Stormwater connection,
Conduit for Telephone & NBN Ready (all
connection points to be within boundary) sites
up to 600m2
Engineered waffle Slab Construction
Termite Protection (to required areas)
Builders’ Warranty Insurance
Building Permit & associated application fees
7 Year Structural Guarantee
3 Month Maintenance Inspection
Fixed Site Cost up to H1 Site Classification
3 hr Colour Consultant Appointment
MPG10 Pine Timber Framing, according to Australian Standards
2700mm Wall Height to Ground Floor & 2400MM Wall Height to First Floor
Truss Roof & Floor joist according to Manufacturer's details
Roof Pitch 22.5 degrees as per Plans
Cat 1 Builders Range Concrete roof tiles as per selection